ALLcrimesfood&drugstaxestelecomcommercehealthconservationtransportationagricultureveteransbrowse all titles »
0

30 U.S.C. § 873Blasting and explosives

submitted 57 years ago by Pub. L. 91-173 to r/title-30-MINERAL-LANDS-AND-MINING · 585 words · no verdicts yet

in plain englishAI-generated · not legal advice

This section limits underground explosives and sets rules for permitted explosives, containers, transport, storage, and separation in coal mines.

(a) Black blasting powder may not be stored or used underground. Mudcaps or other unconfined shots may not be fired underground. (b) Explosives and detonators must stay in separate containers until immediately before blasting. In underground anthracite mines, (1) mudcaps or open, unconfined shake shots may be fired only for battery starting when methane and fire hazards are absent and starting the battery otherwise is impracticable; (2) open shake shots in pitching veins may be fired without methane or fire hazards when removing loose hanging coal another way is too dangerous; and (3) methane must be tested immediately before such shots, which cannot be fired if methane is 1.0% or more until reduced below 1.0%. (c) Except as this subsection allows, underground coal-mine areas may use only permissible explosives, properly strong electric detonators, and permissible blasting devices, used permissibly. Permissible explosives may be fired only with permissible shot-firing units, and only incombustible stemming may be used. Under safeguards, the Secretary may allow more than 20 shots and nonpermissible explosives when sinking surface shafts or slopes through rock. Compressed-air blasting remains allowed. (d) Explosives or detonators carried underground must be in closed, good-condition containers made of nonconductive material. (e) They must be transported in special closed containers in (1) locomotive- or rope-moved cars, (2) belts, (3) shuttle cars, or (4) equipment specially designed for them. (f) Underground supplies for working sections must be in strong section boxes or magazines with no exposed inside metal, at least 25 feet from roadways and power wires, in a dry, well-rock-dusted place protected from roof falls. In pitching beds where that location is impossible, boxes must be in niches cut into solid coal or rock. (g) Explosives and detonators in working places must be in separate closed containers outside the blast line, at least 50 feet from the working face and 15 feet from pipelines, powerlines, rails, or conveyors. If in rib niches, the latter distance is at least 5 feet. Stored explosives and detonators must be at least 5 feet apart.
the actual law source: uscode.house.gov ↗public domain
(a) Limitations on storage and use of black powder and mudcaps

Black blasting powder shall not be stored or used underground. Mudcaps (adobes) or other unconfined shots shall not be fired underground.

(b) Storage of explosives and detonators; mudcaps in anthracite mines; restrictions; tests

Explosives and detonators shall be kept in separate containers until immediately before blasting. In underground anthracite mines, (1) mudcaps or other open, unconfined shake shots may be fired, if restricted to battery starting when methane or a fire hazard is not present, and if it is otherwise impracticable to start the battery; (2) open, unconfined shake shots in pitching veins may be fired, when no methane or fire hazard is present, if the taking down of loose hanging coal by other means is too hazardous; and (3) tests for methane shall be made immediately before such shots are fired and if 1.0 volume per centum or more of methane is present, when tested, such shot shall not be made until the methane content is reduced below 1.0 volume per centum.

(c) Permissible explosives, detonators, and devices; firing; stem boreholes; nonpermissible explosives; compressed air blasting

Except as provided in this subsection, in all underground areas of a coal mine only permissible explosives, electric detonators of proper strength, and permissible blasting devices shall be used and all explosives and blasting devices shall be used in a permissible manner. Permissible explosives shall be fired only with permissible shot firing units. Only incombustible materials shall be used for stemming boreholes. The Secretary may, under such safeguards as he may prescribe, permit the firing of more than twenty shots and allow the use of nonpermissible explosives in sinking shafts and slopes from the surface in rock. Nothing in this section shall prohibit the use of compressed air blasting.

(d) Container construction for carrying explosives or detonators in underground mines

Explosives or detonators carried anywhere underground in a coal mine by any person shall be in containers constructed of nonconductive material, maintained in good condition, and kept closed.

(e) Transportation of explosives or detonators in underground mines

Explosives or detonators shall be transported in special closed containers (1) in cars moved by means of a locomotive or rope, (2) on belts, (3) in shuttle cars, or (4) in equipment designed especially to transport such explosives or detonators.

(f) Storage of explosives and detonators in working sections of underground mines; containers; locations

When supplies of explosives and detonators for use in one or more working sections are stored underground, they shall be kept in section boxes or magazines of substantial construction with no metal exposed on the inside, located at least twenty-five feet from roadways and power wires, and in a dry, well rock-dusted location protected from falls of roof, except in pitching beds, where it is not possible to comply with the location requirement, such boxes shall be placed in niches cut into the solid coal or rock.

(g) Location of explosive and detonator containers in working places of underground mines

Explosives and detonators stored in the working places shall be kept in separate closed containers which shall be located out of the line of blast and not less than fifty feet from the working face and fifteen feet from any pipeline, powerline, rail, or conveyor, except that, if kept in niches in the rib, the distance from any pipeline, powerline, rail, or conveyor shall be at least five feet. Such explosives and detonators, when stored, shall be separated by a distance of at least five feet.

Source credit: (Pub. L. 91–173, title III, § 313, Dec. 30, 1969, 83 Stat. 785.)